  "@context": {
    "schema": "http://schema.org/",
    "dcterms": "http://purl.org/dc/terms/",
    "dcat": "http://www.w3.org/ns/dcat#",
    "wd": "https://www.wikidata.org/entity/",
    "ex": "https://example.org/"
  },
  "@id": "ex:instrument-icpms-lab42",
  "@type": [
    "schema:Product",
    "schema:Thing"
  ],
  "schema:additionalType": [
    "wd:Q223767"
  ],
  "schema:name": "ICP-MS System (Stable Isotope Geochemistry Lab)",
  "schema:description": "Inductively coupled plasma mass spectrometer for trace element and isotope ratio analysis of geological and environmental samples. Equipped with collision/reaction cell for polyatomic interference removal. Typical applications include REE patterns, U-Pb geochronology screening, and water quality trace metals.",
  "schema:alternateName": [
    "ICP-MS",
    "Lab 42 Quadrupole ICP-MS"
  ],
  "schema:identifier": [
    {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": "https://doi.org",
      "schema:value": "10.xxxx/instrument.icpms.lab42",
      "schema:url": "https://doi.org/10.xxxx/instrument.icpms.lab42"
    },
    {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": "inventoryNumber",
      "schema:value": "GEOL-LAB42-ICPMS-003"
    }
  ],
  "schema:url": "https://example.org/facilities/lab42/icpms",
  "schema:manufacturer": {
    "@type": [
      "schema:Organization"
    ],
    "schema:name": "Agilent Technologies",
    "schema:identifier": {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": "https://ror.org",
      "schema:value": "03kbsn367",
      "schema:url": "https://ror.org/03kbsn367"
    }
  },
  "schema:model": {
    "@type": [
      "schema:ProductModel"
    ],
    "schema:name": "Agilent 7900 ICP-MS",
    "schema:identifier": {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": "serialNumber",
      "schema:value": "JP19200456"
    }
  },
  "schema:category": [
    {
      "@type": [
        "schema:DefinedTerm"
      ],
      "schema:name": "Inductively Coupled Plasma Mass Spectrometry",
      "schema:termCode": "LAB21",
      "schema:identifier": {
        "@type": [
          "schema:PropertyValue"
        ],
        "schema:propertyID": "https://vocab.nerc.ac.uk/collection/L05/current/",
        "schema:value": "LAB21",
        "schema:url": "https://vocab.nerc.ac.uk/collection/L05/current/LAB21/"
      },
      "schema:inDefinedTermSet": "https://vocab.nerc.ac.uk/collection/L05/current/"
    }
  ],
  "schema:owner": {
    "@id": "https://ror.org/03m2x1q45",
    "@type": [
      "schema:Organization"
    ],
    "schema:name": "University of Arizona",
    "schema:identifier": {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": "https://ror.org",
      "schema:value": "03m2x1q45",
      "schema:url": "https://ror.org/03m2x1q45"
    }
  },
  "schema:contributor": [
    {
      "@type": [
        "schema:Role"
      ],
      "schema:roleName": {
        "@type": [
          "schema:DefinedTerm"
        ],
        "schema:name": "Laboratory Manager",
        "schema:inDefinedTermSet": "https://credit.niso.org/",
        "schema:termCode": "resources"
      },
      "schema:contributor": {
        "@id": "https://orcid.org/0000-0001-9876-5432",
        "@type": [
          "schema:Person"
        ],
        "schema:name": "Park, Soo-Jin",
        "schema:identifier": {
          "@type": [
            "schema:PropertyValue"
          ],
          "schema:propertyID": "https://orcid.org",
          "schema:value": "0000-0001-9876-5432",
          "schema:url": "https://orcid.org/0000-0001-9876-5432"
        },
        "schema:contactPoint": {
          "@type": [
            "schema:ContactPoint"
          ],
          "schema:email": "spark@arizona.edu"
        }
      }
    }
  ],
  "schema:additionalProperty": [
    {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": [
        "detectionLimit"
      ],
      "schema:name": "Detection limit (most elements)",
      "schema:value": "sub-ppt",
      "schema:unitText": "parts per trillion"
    },
    {
      "@type": [
        "schema:PropertyValue"
      ],
      "schema:propertyID": [
        "massRange"
      ],
      "schema:name": "Mass range",
      "schema:value": "2-260",
      "schema:unitText": "amu"
    }
  ],
  "schema:validFrom": "2019-06-01",
  "schema:validThrough": "2026-01-15",
  "schema:hasPart": [
    {
      "@type": [
        "schema:Thing"
      ],
      "@id": "ex:component-autosampler-lab42",
      "schema:name": "Autosampler for ICP-MS",
      "schema:description": "Automated sample introduction system with 240-position sample tray and integrated rinse station",
      "schema:alternateName": "ASX-560 Autosampler",
      "schema:identifier": {
        "@type": [
          "schema:PropertyValue"
        ],
        "schema:propertyID": "serialNumber",
        "schema:value": "ASX-2019-0789"
      },
      "schema:additionalType": "wd:Q16653419",
      "schema:manufacturer": {
        "@type": [
          "schema:Organization"
        ],
        "schema:name": "Agilent Technologies"
      },
      "schema:model": {
        "@type": [
          "schema:ProductModel"
        ],
        "schema:name": "ASX-560"
      },
      "schema:additionalProperty": [
        {
          "@type": [
            "schema:PropertyValue"
          ],
          "schema:propertyID": [
            "capacity"
          ],
          "schema:name": "Sample capacity",
          "schema:value": 240
        }
      ]
    },
    {
      "@id": "ex:component-chiller-lab42"
    }
  ],
  "schema:relatedLink": [
    {
      "@type": [
        "schema:CreativeWork",
        "dcat:Relationship"
      ],
      "schema:name": "Agilent 7900 ICP-MS User Manual",
      "schema:description": "Complete user and maintenance manual for the Agilent 7900 quadrupole ICP-MS system",
      "schema:url": "https://www.agilent.com/cs/library/usermanuals/public/7900-icpms-manual.pdf"
    },
    {
      "@type": [
        "schema:CreativeWork",
        "dcat:Relationship"
      ],
      "schema:name": "2025 Annual Calibration Report",
      "schema:url": "https://example.org/calibration/icpms-lab42-2025.pdf"
    }
  ],
  "schema:subjectOf": {
    "@id": "ex:metadata-instrument-icpms-lab42",
    "@type": [
      "schema:DigitalDocument"
    ],
    "schema:dateModified": "2026-03-31",
    "schema:about": {
      "@id": "ex:instrument-icpms-lab42"
    },
    "dcterms:conformsTo": [
      {
        "@id": "https://w3id.org/cdif/bbr/metadata/instrumentDescription/v0.1"
      }
    ]
  }
}